Abstract
Fenton process, as one of the most conventional advanced oxidation processes, is widely used in the treatment of specific wastewaters, especially landfill leachate. In current study, the main target was to evaluate some neglected aspects of Fenton process in operational applications. Thus, three novel responses were introduced. Mass removal efficiency evaluates overall recalcitrant destruction by establishing organics mass balance pre- and post-Fenton treatment. This differentiates it from conventional chemical oxygen demand removal, since mass removal efficiency basically considers the whole mixture and not only the supernatant. The mass content ratio response provides a measure to evaluate the remaining organics in the sludge. Therefore, a borderline mode considering these limitations leads to best feasible field operations. It was found that mass content ratio for effluent reacted conversely to the sludge in response to coagulation. By increasing the coagulant dosage, coagulation improved and the sludge ratio increased in result. For the mass removal efficiency response, it seemed that appropriate balance of the oxidation/coagulation had considerable role through Fe2+ dosage and [H2O2]/[Fe2+] ratio. Finally, by including further conventional parameters such as sludge quantity, the best operational conditions (X1 = 5.7, X2 = 16, X3 = 207 mM) were optimized by response surface methodology to 27.4% and 14.4% for sludge and effluent mass content ratio, respectively, and 58.1% for mass removal efficiency. The results were in good agreement with determination coefficient (R2) of 0.94–0.97, prediction R2 of 0.80–0.93 and coefficient of variation less than 10.
Graphical Abstract
Highlights
- Showing mass removal efficiency (MRE) as an overall measure of recalcitrant breakdown and mass content ratio (MCR) for polluting potential of Fenton products
- Application of response surface methodology for simultaneous optimization of responses
- Investigation in relative importance of oxidation and coagulation in Fenton process
- Establishment of mass balance in pre- and post-treatment of Fenton for pollutants
Keywords
Letters to Editor
[1] Letters that include statements of statistics, facts, research, or theories should include appropriate references, although more than three are discouraged.
[2] Letters that are personal attacks on an author rather than thoughtful criticism of the author’s ideas will not be considered for publication.
[3] Letters can be no more than 300 words in length.
[4] Letter writers should include a statement at the beginning of the letter stating that it is being submitted either for publication or not.
[5] Anonymous letters will not be considered.
[6] Letter writers must include their city and state of residence or work.
[7] Letters will be edited for clarity and length.
Send comment about this article